X-band Electron Spin Resonance
|
|
|
|
|
|
Manufacturer:
|
Bruker |
Measurements:
|
cw ESR (3.6-300 K, sensitivity 10-9 spins, lock-in detection, rapid and transient mode, maximum power 150mW); pulsed ESR (2.6-300 K, dead time 74 ns, maximum power 300W, cavity bandwith 300MHz); |
|
Temperature range:
|
2.6-300 K |
Magnetic field:
|
±1.4T (horizontal) |
Year of launch:
|
2016 |
|
|
|
|
Physical Property Measurement System (PPMS) -9
|
|
|
|
|
|
Manufacturer:
|
Quantum Design, Inc. |
Measurements:
|
DC magnetic susceptibility (2-400 K, sensitivity 10
-5emu, detection limit 30 emu); |
|
AC magnetic susceptibility (2-350 K, frequency range 10-10000 Hz, amplitude 1-17 Oe, sensitivity 10
-6emu); |
|
Specific heat capacity (1.9-400 K); |
|
DC and AC electrical transport; |
|
Heat transport |
Temperature range:
|
1.9-400 K |
Magnetic field:
|
0-±9 T (vertical) |
Excitation rate:
|
up to 200 Oe/s |
Year of launch:
|
2011 |
|
|
Magnetic Property Measurement System (MPMS)
-XL
with Superconductive QUantum Interference Device (SQUID)
|
|
|
|
|
|
Manufacturer:
|
Quantum Design, Inc. |
Measurements:
|
DC magnetic susceptibility (sensitivity 10
-7emu); |
|
AC magnetic susceptibility (frequency range 0.1-1488 Hz, amplitude 1-5 Oe, sensitivity 10
-6emu); |
|
Opto-magnetic properties |
Temperature range:
|
1.8-380 K |
Magnetic field:
|
0-±5 T (vertical) |
Options:
|
Horizontal rotator for DC measurement (0-360 deg.; resolution ~2 deg.) |
|
Helium-3 Refrigerator (0.48-2.0 K, for both DC and AC) |
Year of launch:
|
2004 |
|
|
TH2828 Precision LCR Meter (Dielectric System)
|
|
|
|
|
|
Manufacturer:
|
Globalmediapro Ltd. |
Measurements:
|
Temperature-dependent dielectric permittivity |
Temperature range:
|
100-500 K |
Frequency range:
|
10 Hz - 1 MHz |
Accuracy:
|
0.1 pF |
Year of purchase:
|
2010 |
|
|
|
SuperNova Dual Atlas CCD diffractometer
|
|
|
|
|
|
Manufacturer:
|
Agilent Technology |
Measurements:
|
Single crystal structure |
X-ray source:
|
Mo K
αradiation (λ = 0.71073 Å) and Cu K
αradiation (λ = 1.5418 Å) |
Temperature range:
|
15-500 K |
Year of purchase:
|
2011 |
|
|
Nonius Kappa CCD Diffractometer
|
|
|
|
|
|
Measurements:
|
Single crystal structure |
X-ray source:
|
Graphite monochromated Mo K
αradiation (λ = 0.71073 Å) |
Temperature range:
|
90-375 K (with Oxford Cyrostream 600 Temperature Control System) |
Year of purchase:
|
1999 |
|
|
|
VDS-80M3 High Vacuum Sublimation Purification Furnace
|
|
|
|
|
|
Manufacturer:
|
TECHNOL |
Vacuum:
|
High vacuum 1×10
-4Pa, low vacuum 1 Pa |
Heating Temperature limit:
|
800, 600 and 500 deg. Celsius respectively, in 3 regions |
Year of purchase:
|
2009 |
|
|
|
Glovebox SG1200/750TS
|
|
|
|
|
|
Provids an inert atmosphere free of water and oxygen (< 0.01 ppm).
|
Manufacturer:
|
Vigor Gas Purification Technologies Co., Ltd. |
Option:
|
Refrigerator down to -30 deg. Celsius |
Year of purchase:
|
2012 |
|
|
|
Glovebox VG1200/750TS
|
|
|
|
|
|
Provids an inert atmosphere free of water and oxygen (< 0.01 ppm).
|
Manufacturer:
|
Vigor Gas Purification Technologies Co., Ltd. |
Year of purchase:
|
2009 |
|
|
Solvent Purification Systems MB-SPS-800
|
|
|
|
|
|
Drying and dispensing solvents in an easy, safe and fast way.
|
Manufacturer:
|
MBRAUN |
Available solvents:
|
Tetrahydrofuran, diethyl ether, dimethyl formamide, acetonitrile, toluene |
Year of purchase:
|
2012 |
|
|
|